[edit] Beschreibung

Description

A code violation waiting to happen: In this case, penetrants have been punched and burned through a drywall assembly required to have a fire-resistance rating. The integrity of the drywall has been seriously compromised at the through-penetration and will be fixed with nothing but drywall mud, whereas a solidly framed opening could have been spared out and sealed in a manner preserving bounding by a speciality firestop subcontractor. Details of this nature illustrate the difference between drywall testing and certification and the compromises made in the field, which would have a very difficult time passing actual testing. It must also be noted, that since the penetrants are suspended independently from the concrete slab above, they are not likely to follow the fire-induced motion that the drywall will undergo due to calcining/loss of chemically bound water. To avoid a multiplication of errors, consultants can take the test scale into account.

Source

own work

Date

27. May 2007

Author

Achim Hering

Permission
(Reusing this image)

see below


[edit] Licensing

Public domain I, the copyright holder of this work, hereby release it into the public domain. This applies worldwide.

In case this is not legally possible:
I grant anyone the right to use this work for any purpose, without any conditions, unless such conditions are required by law.


Afrikaans | Alemannisch | Aragonés | العربية | Asturianu | Български | Català | Česky | Cymraeg | Dansk | Deutsch | Eʋegbe | Ελληνικά | English | Español | Esperanto | Euskara | Estremeñu | فارسی | Français | Galego | 한국어 | हिन्दी | Hrvatski | Ido | Bahasa Indonesia | Íslenska | Italiano | עברית | Kurdî / كوردی | Latina | Lietuvių | Latviešu | Magyar | Македонски | Bahasa Melayu | Nederlands | ‪Norsk (bokmål)‬ | ‪Norsk (nynorsk)‬ | 日本語 | Polski | Português | Ripoarisch | Română | Русский | Shqip | Slovenčina | Slovenščina | Српски / Srpski | Svenska | ไทย | Tagalog | Türkçe | Українська | Tiếng Việt | Walon | ‪中文(简体)‬ | ‪中文(繁體)‬ | zh-yue-hant | +/-

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeDimensionsUserComment
current00:22, 28 May 20072,348×3,544 (832 KB)Achim Hering ({{Information |Description=A code violation waiting to happen: In this case, penetrants have been punched and burned through a '''drywall''' assembly required to have a fire-resistance rating. The integrity of the drywall has been seriously compromise)
The following pages on the English Wikipedia link to this file (pages on other projects are not listed):